PROTEGO®
Pressure and Vacuum Relief Valves with Flame Arrester

Cutaway 3D render of a red industrial valve showing internal components inside the housing, with a gray side-mounted actuator on a black background.

Breather Valves with Integrated Flame Arrester - Emission and Explosion Protection

Pressure and Vacuum Relief Valves Soupape de surpression et dépression A pressure and vacuum relief valve is a pressure equalization valve for impermissible pressure and vacuum in a closed system. with integrated  Flame Arrester Unit combine two critical safety functions into a single unit: controlled tank breathing and protection against flame transmission. 

These valves combine pressure control and explosion protection Protection antidéflagrante An explosion protection is a flame arrester that prevents flame propagation into plant sections to be protected during explosions. in a single, type approved device Appareil A device is a pipe component that influences the media flow by opening, closing, or partially shutting off the flow channel or by dividing or mixing the media flow. . They prevent atmospheric deflagration and, depending on the design, also protect against endurance burning Endurance burning Stabilized burning for an unlimited time. . This ensures that both operational integrity and safety risks are addressed by one device which provides a durable and easy to maintain solution. In addition these valves reduce emissions and prevent unnecessary air intake. This supports product conservation and stable operating conditions.

Please select a valve from our range below

Filter products
Pressure / Vacuum
Explosion Group
Combustion Process
Flange Connection Size DN
Material
Heating jacket
Approvals
Flange or thread connection type
horizontal / vertical connection
Product Name
VD/TS
Pressure/Vacuum Relief Valve
vacuum range
-2 up to -25 mbar
pressure range
3.5 up to 50 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
SV/E
Vacuum Relief Valve
vacuum range
-2 up to -60 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC
UB/SF
Pressure/Vacuum Diaphragm Valve
vacuum range
-3.5 up to -35 mbar
pressure range
3.5 up to 140 mbar
Explosion Group
D / IIA
C / IIB1
C / IIB2
C / IIB3
PV/EB
Pressure/Vacuum Relief Valve
vacuum range
-3.5 up to -35 mbar
pressure range
2 up to 210 mbar
Explosion Group
IIA1
D / IIA
VD/SV-AD, VD/SV-ADL
Pressure/Vacuum Relief Valve
vacuum range
-2 up to -35 mbar
pressure range
-3.5 up to 35 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
P/EB
Pressure Relief Valve
pressure range
3.5 up to 210 mbar
Explosion Group
IIA1
D / IIA
P/EBR
Pressure Relief Valve
pressure range
3.5 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
PV/EBR
Pressure/Vacuum Relief Valve
vacuum range
-3.5 up to -50 mbar
pressure range
2 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
BE/HR-D
Pressure Relief Valve
pressure range
2 up to 35 mbar
Explosion Group
IIA1
D / IIA
D-SVL-EB-IIA
Pressure Relief Valve
pressure range
2 up to 60 mbar
Explosion Group
IIA1
D / IIA
DE-S-IIC
High Velocity Pressure Relief Valve
pressure range
60 up to 350 mbar
Explosion Group
B / IIC
DE/S-IIB
High Velocity Pressure Relief Valve
pressure range
100 up to 500 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
DE/S-IIB3
High Velocity Pressure Relief Valve
pressure range
100 up to 500 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
DE/S-MK VI - IIB3
High Velocity Pressure Relief Valve
pressure range
60 up to 350 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
P/EB-E
Pressure Relief Valve
pressure range
3.5 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
P/EBR-E-IIB1
Pressure Relief Valve
pressure range
3.5 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
P/EBR-E-IIB3
Pressure Relief Valve
pressure range
3.5 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
PV/EB-E
Pressure/Vacuum Relief Valve
vacuum range
-3.5 up to -35 mbar
pressure range
2 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
PV/EBR-E-IIB1
Pressure/Vacuum Relief Valve
vacuum range
-3.5 up to -50 mbar
pressure range
2 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
PV/EBR-E-IIB3
Pressure/Vacuum Relief Valve
vacuum range
-3.5 up to -50 mbar
pressure range
2 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB3
UB/DF
Pressure Diaphragm Valve
pressure range
3.5 up to 140 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
UB/SF-G
Pressure/Vacuum Diaphragm Valve
vacuum range
-3.5 up to -3.5 mbar
pressure range
3.5 up to 140 mbar
Explosion Group
D / IIA
C / IIB1
C / IIB2
C / IIB3
UB/SF-IIA1
Pressure/Vacuum Diaphragm Valve
vacuum range
-3.5 up to -35 mbar
pressure range
3.5 up to 150 mbar
Explosion Group
IIA1
UB/VF
Vacuum Diaphragm Valve
vacuum range
-3.5 up to -35 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
V/SV-AD-IIB3
Vacuum Relief Valve
vacuum range
-2 up to -35 mbar
Explosion Group
C / IIB3
VD-SV-EB
Pressure/Vacuum Relief Valve
vacuum range
-2 up to -60 mbar
pressure range
2 up to 60 mbar
Explosion Group
IIA1
D / IIA
VD/SV-HR
Pressure/Vacuum Relief Valve
vacuum range
-2 up to -35 mbar
pressure range
3.5 up to 35 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
VD/SV-HRL
Pressure/Vacuum Relief Valve
vacuum range
-2 up to -35 mbar
pressure range
3.5 up to 35 mbar
Explosion Group
IIA1
D / IIA

Highlights of PROTEGO® Breather Valves

10% Technology
(set pressure close to relieving pressure)
Extreme tightness
reduced product losses
ZETOP
Zero Emission at Tank Operating Pressure
Lifecycle confidence
with maintenance-friendly designs and global service
Zero flashback incidents
when sized, located, and maintained per application
Very high flow capacity
for your operations

How It Works

PROTEGO® 10% Technology

PROTEGO® Valves use a full- lift Course Lift is the actual travel of the valve pallet from the main valve out of the closed position. -type technology. The valve reaches full lift at 10% accumulation above the set pressure Pression de réponse Set pressure is the gauge pressure at the device inlet at which the relief device is set to start opening under service conditions. . This allows the valve to deliver full relieving capacity quickly, ensuring that required mass flow is safely discharged before pressure limits are exceeded.

Conventional low-pressure valves require 80% to 100% overpressure Surpression Overpressure refers to an increase in pressure in a system or vessel above the normal operating pressure. to reach full lift. These open earlier and close later, which increases product losses. In contrast, PROTEGO® Valves open later and re-seat earlier. This improves pressure control and reduces unnecessary vapor release.

 

PROTEGO® Valve and Flame Arrester performance is assured for all relief and explosion scenarios defined in the design case. The pressure drop of the combined device (Flame Arrester and Pressure/Vacuum Valve) is determined on a TÜV-certified flow test rig according to API 2000. The entire device is type approved to ATEX or other relevant international standards for the determined explosion scenarios.

The units are extremely maintenance-friendly and have very low leak rates to reduce explosion risk and ensure compliance with environmental requirements.

Red combination flame arrester and vent valve in cutaway view, showing the internal housing and safety components.

The devices have performed as promised with low leak rates and minimal maintenance effort. We highly recommend them. 

Project Manager

PetroChina

We provide engineered safety solutions.

Since 1954, PROTEGO® has built and provided Flame Arresters, Pressure and Vacuum Relief Valves and Tank Equipment, now with the help of more than 750 employees worldwide.

Engineering and Compliance

Correct valve selection is critical for safe and effective operation. Key selection criteria include:

Function
pressure/ vacuum Dépression Vacuum is the pressure in an enclosed space that is lower than the ambient pressure. relief, protection against atmospheric deflagration or endurance burning
Installation
vent to atmosphere or vent to header, VRU, flare, etc.
Process of combustion
endurance burning, atmospheric deflagration or in-line detonation
Operating conditions
polymerization, condensation, corrosion, operating temperatures and pressures

Valve sizing is based on required volume flow and maximum allowable pressure. Certified volume flow diagrams are available to support design.

Material selection must follow plant and engineering specifications. Options such as metallic or soft sealing are selected based on operating conditions.

Key Features and Design Characteristics

Pressure drop is determined on TUV certified flow test rig according to API 2000 requirements for the combined device (Flame Arrester and Pressure Vacuum Valve).

The valve reaches full lift at 10% overpressure above the set pressure. This allows set pressures to be defined at 10% below the maximum allowable working pressure of the tank. This improves utilization of allowable pressure limits and reduces product losses.

The built-in flame arrester protects against atmospheric deflagration and, in some designs, endurance burning. This ensures that ignition from external sources does not propagate into the system. For in-line valves connected to a vent header Vent header Piping system that collects and delivers the relief gases to the vent stack. combination valve - detonation arresters Arrête-flammes antidétonation Flame arrester designed to prevent the transmission of a detonation. are type approved to ATEX or other international standards.

The valve reduces emissions almost up to the set pressure. This limits vapor losses during normal operation and supports conservation of stored products.

High flow capacity allows required volume flow to be handled with smaller valve sizes. This reduces equipment size and associated costs.

The flame arrester is isolated from the product when the valve is closed. This reduces contamination and extends maintenance intervals.

Operational Benefits

Reduced emissions
tightness far above the normal standard
Reduced product loss
10% full-lift technology allows later opening 
Reliable Protection
flow and flame transmission testing of the combined device
Lower maintenance impact 
due to modular, serviceable design

Get in Touch

Contact our engineers for your 
individual requirements