Free-standing Alcohol Storage Tanks

Integrated Venting Strategies

Free-standing alcohol storage tanks need engineered venting solutions for flammable vapors and fire scenarios. Without a frangible roof-to-shell connection, emergency relief is crucial. 
Protection involves deflagration-safe venting, pressure and vacuum relief, and emergency functions. Depending on regulations, flame protection may require endurance-burning capability.

Highlights

Engineered Venting Solutions
Meeting regulatory requirements and managing flammable alcohol vapors.
Compliance 
supported by documented testing and approvals
Emergency Relief for Fire Exposure
Providing sufficient relief capacity for tanks exposed to fire scenarios.
Combining relief devices and Flame Arresters for alcohol storage safety.

Products for Alcohol Storage

VD/TS
Pressure/Vacuum Relief Valve
vacuum range
-2 up to -25 mbar
pressure range
3.5 up to 50 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
SV/E
Vacuum Relief Valve
vacuum range
-2 up to -60 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC
ER/VH
Pressure Relief Valve
pressure range
25 up to 60 mbar
P/EBR-E-IIB3
Pressure Relief Valve
pressure range
3.5 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
LH/AD
Deflagration Flame Arrester, End-of-Line
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Protection Concepts without Emergency Relief Venting

For free-standing alcohol storage tanks where emergency venting is not required based on applicable standards, fire risk assessment, or tank design assumptions, protection concepts focus on normal tank breathing and explosion prevention.

Highlights

Flashback prevention
for safe operation
Lower emissions
and reduced product losses 
Compliant relief capacity 
for alcohol storage
Process opimization support 
via expert consulting service at project FEED

Products for Alcohol Storage

VD/TS
Pressure/Vacuum Relief Valve
vacuum range
-2 up to -25 mbar
pressure range
3.5 up to 50 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
SV/E
Vacuum Relief Valve
vacuum range
-2 up to -60 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC
BE/HR-E-IIB3
Deflagration Flame Arrester, endurance burning proof, End-of-Line
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
P/EBR-E-IIB3
Pressure Relief Valve
pressure range
3.5 up to 210 mbar
Explosion Group
IIA1
D / IIA
C / IIB1
LH/AD
Deflagration Flame Arrester, End-of-Line
Explosion Group
IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

The devices have performed as promised with low leak rates and minimal maintenance effort. We highly recommend them. 

Get in Touch

Contact our engineers for your 