Features
Function and Description

Highly Developed Vacuum Relief Valve
The SV/E-1-0 Type PROTEGO® valve is a highly developed vacuum relief valve Soupape de dépression A vacuum relief valve is used to ventilate a part of the system and protects it from impermissible underpressure. with excellent flow performance. It is primarily used as a device Appareil A device is a pipe component that influences the media flow by opening, closing, or partially shutting off the flow channel or by dividing or mixing the media flow. for relieving vacuum Dépression Vacuum is the pressure in an enclosed space that is lower than the ambient pressure. in tanks, containers, and process engineering equipment. The valve offers reliable protection against vacuum and prevents in-breathing of air close to the set pressure Pression de réponse Set pressure is the gauge pressure at the device inlet at which the relief device is set to start opening under service conditions. .

Full Lift Technology
The device will start to open as soon as the set pressure is reached and only requires 10% overpressure Surpression Overpressure refers to an increase in pressure in a system or vessel above the normal operating pressure. to reach full lift Course Lift is the actual travel of the valve pallet from the main valve out of the closed position. . Continuous investments in and a commitment to research and development have allowed PROTEGO® to develop a low pressure valve which has the same opening characteristics as a high pressure safety relief valve. This “Full Lift Type” technology allows the valve to be set at just 10% below the maximum allowable working pressure of the tank and still safely vent the required mass flow.

Advanced Manufacturing Technology
Due to our highly developed manufacturing technology, the tank pressure Pression de la cuve Tank pressure is the pressure within a tank. is maintained up to set pressure with a tightness that is far superior to the conventional standard. This feature is achieved by valve seats made of high quality stainless steel and with precisely lapped valve pallets (1) or with an air cushion seal Joint A seal prevents or limits unwanted transfer of product from one container to another. Seal is used as superordinate term for all types of sealing elements. (2) in conjunction with high quality FEP diaphragm Membrane A diaphragm is a thin layer of material, which has a large surface area. . The valve pallets are also available with a PTFE seal to prevent the valve pallets from sticking when sticky products are used, and they enable the use of corrosive substances. After the vacuum is released, the valve reseats and provides a tight seal again.
Dimensions
To select the nominal size Diamètre nominal The nominal size is an alphanumeric designation of size for components in a piping system, used for reference purposes, comprising the letters DN followed by a dimensionless integer that is indirectly related to the physical size of the bore or outside diameter of the connections, expessed in millimeters. (DN), use the flow capacity chart on the following page
| DN | 50 / 2" | 80 / 3" | 100 / 4" | 150 / 6" | 200 / 8" | 250 / 10" | 300 / 12" |
| a | 140 / 5.51 | 170 / 6.69 | 190 / 7.48 | 230 / 9.06 | 300 / 11.81 | 325 / 12.80 | 425 / 16.73 |
| b | 75 / 2.95 | 85 / 3.35 | 95 / 3.74 | 120 / 4.72 | 140 / 5.51 | 165 / 6.50 | 205 / 8.07 |
| c | 205 / 8.07 | 205 / 8.07 | 285 / 11.22 | 360 / 14.17 | 405 / 15.94 | 460 / 18.11 | 500 / 19.69 |
| d | 170 / 6.69 | 235 / 9.25 | 280 / 11.02 | 335 / 13.19 | 445 / 17.52 | 505 / 19.88 | 505 / 19.88 |
| e | 215 / 8.46 | 215 / 8.46 | 255 / 10.04 | 335 / 13.19 | 425 / 16.73 | 460 / 18.11 | 625 / 24.61 |
Dimensions in mm / inches
Dimensions for vacuum relief valve with heating jacket upon request
Material selection for housing
| Design | - | B | C | D |
| Housing | - | Steel | Stainless Steel | Aluminium |
| Heating jacket (SV / E-1-0-H...) | - | - | Stainless Steel | - |
| Valve seat | - | Stainless Steel | Stainless Steel | Stainless Steel |
| Sealing | - | PTFE | PTFE | PTFE |
Option: Housing with ECTFE-lining
Design D and Special materials upon request
Material selection for vacuum valve pallet
| Design | A | B | C | D | E | F |
| vacuum range [mbar] [inch W.C.] | -2,0 up to -3,5 -0.8 up to -1.4 | <-3,5 up to -14 <-1.4 up to 5.6 | <-14 up to -35 <-5.6 up to -14 | <-35 up to -60 <-14 up to -24 | <-14 up to -35 <-5.6 up to -14 | <-35 up to -60 <-14 up to -24 |
| Valve pallet | Aluminium | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Sealing | FEP | FEP | Metal to Metal | Metal to Metal | PTFE | PTFE |
Special materials(Alu-coated, Titanium, Hastelloy) and higher vacuum settings upon request
Flange connection type
| EN 1092-1; Form B1 |
| ASME B16.5 CL 150 R.F. |
other types upon request
Design Types and Specifications
The valve pallet Clapet Valve pallet is the generic term for the assembly that rests on the valve seat. is weight-loaded. Higher vacuum can be achieved upon request with a special spring Ressort A spring is a spiral of wire which returns to its original shape after it is pressed or pulled. -loaded design.There are two different designs:
Additional special devices available upon request.
Settings
| Vacuum: | -2.0 mbar | -60 mbar |
| -0.8 inch W.C. | -24 inch W.C. |
Higher vacuum settings upon request.
Flow Capacity Chart
The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.