16.07.2026
Blog

Storage Tank Safety with Combined Devices

Storage Tank Safety with the PROTEGO® Combined Pressure/Vacuum Relief Valves Flame Arresters Solution

ISO 16852 mandates combined flow and flame transmission testing when Pressure/Vacuum Relief Valves (P/V Valves) are used in combination with flame arresters.

However, many installations in the field are not tested as a combined unit and therefore don’t comply with ISO 16852 requirements. These issues may introduce increased risk in routine operations and emergency relief. A proven method of mitigating this risk is to implement fully tested, integrated solutions, such as PROTEGO®’s combined Pressure/Vacuum Relief Valves Flame Arresters unit for storage tank safety.

Why Testing a Combined Unit is Important

Risks of Installing Flame Arresters Below the P/V Valve

Placing a flame arrester beneath the relief valve can result in additional hazards, such as:

PROTEGO® offers Pressure/Vacuum Relief Valves that include an Integrated Flame Arrester, designed for safer protection of storage tanks.

PROTEGO® provides devices that include a built-in flame arrester, which meets the flow test and explosion standards of ISO 16852 and offers extra protection for the environment and storage tanks.

Certified Compliance

  • EN ISO 16852 and ATEX 2014/34/EU approved PROTEGO® VD/TS.
  • Valve and flame arrester performance is guaranteed for all relief and explosion scenarios that may occur in accordance with the design case.

Certified Flow Performance

The flow curve of the combined device Appareil A device is a pipe component that influences the media flow by opening, closing, or partially shutting off the flow channel or by dividing or mixing the media flow. (flame arrester and P/V valve) is measured using a TÜV-certified flow test rig that complies with API 2000 (7th Edition) Standard.

Built for Real Operating Conditions

Maintenance Without Compromise

  • Extremely maintenance-friendly construction.
  • Routine inspection of the flame arrester results in no loss of explosion mitigation.

Lower Emissions and Risk

Very low leak rates in the parts per million (ppm) range help reduce explosion risks and promote environmental compliance.

In summary

In summary, combining a P/V valve and a flame arrester necessitates verified, integrated performance and is not as simple as it may seem in the first place. Installations can experience pressure losses, restricted flow, or chattering if testing is not performed on the combined unit; maintenance can also become complex, risky and very cost intense. PROTEGO® addresses these challenges by providing independent third party tested, integrated, certified solutions that comply to ISO 16852 and API 2000 standards, are engineered for harsh environments, are maintenance optimized, and are designed to reduce emissions and risk to protect people and the environment.